Reflective Ultrasonic Sensors | Liquids | General Purpose & Intrinsically Safe

EchoPod UG01 UG03 Reflective Ultrasonic Multi-Function Liquid Level Transmitter EchoPod UG06 UG12 Reflective Ultrasonic Liquid Level Transmitter EchoTouch US01 US03 Reflective Ultrasonic Liquid Level Transmitter EchoTouch US06 US12 Reflective Ultrasonic Liquid Level Transmitter
Series UG01-03 UG06-12 US01-03 US06-12
Classification General purpose General purpose Intrinsically safe Intrinsically safe
Media Liquids Liquids Liquids Liquids
Application Day tank, skid or machine, cooling tower, IBC or drum, process tank, small waste sump Bulk storage, neutralization tank, clarifier, large waste sump Day tank, skid or machine, IBC or drum, process tank, small waste sump Bulk storage, neutralization tank, clarifier, large waste sump
Condensation Yes Yes Yes Yes
Range 9.8′ (3m) 39.3′ (12m) 9.8′ (3m) 39.3′ (12m)
Output 4-20 mA + (4) SPST relays 4-20 mA 4-20 mA 4-20 mA, HART
Display No Yes No Yes
Configuration WebCal software Push button, WebCal software WebCal software Push button, HART, WebCal software
Termination Cable Conduit Cable Conduit
Mount 2″ NPT (G) 2″, 3″ NPT (G) 2″ NPT (G) 2″, 3″ NPT (G)
Temperature -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.)
Max. pressure 30 PSI (2 bar) 30 PSI (2 bar) 30 PSI (2 bar) 30 PSI (2 bar)
Trans. material PVDF PVDF PVDF PVDF

Ultrasonic Sensors | Liquids | General Purpose & Intrinsically Safe

Series DL10 DL14 DL24 LU23-29 LU80-84 LU20
Classification General purpose General purpose General purpose General purpose General purpose Intrinsically safe
Media Liquids Liquids Liquids Liquids Liquids Liquids
Application Chemical feed, skid or machine, IBC or drum Chemical feed, skid or machine, IBC or drum Day tank, skid or machine Bulk storage, day tank, waste sump Bulk storage, day tank, waste sump Bulk storage, day tank, waste sump
Condensation Minimal Minimal Minimal Minimal Minimal Minimal
Range 49.2″ (1.25m) 49.2″ (1.25m) 9.8′ (3m) 32.8′ (10m) 32.8′ (10m) 18′ (5.4m))
Output 4-20 mA 4-20 mA + (4) SPST relays 4-20 mA + (4) SPST relays 4-20 mA 4-20 mA 4-20 mA
Display No No No No Yes Yes
Configuration WebCal software WebCal software WebCal software WebCal software Push button Push button
Termination Cable Cable Cable Cable Conduit Conduit
Mount 1″ NPT (G) 1″ NPT (G) 1″ NPT (G) 1″, 2″ NPT (G) 1″, 2″ NPT (G) 2″ NPT (G)
Temperature 20º F. (-7º C.) to 140º F. (60º C.) 20º F. (-7º C.) to 140º F. (60º C.) 20º F. (-7º C.) to 140º F. (60º C.) -4º F. (-20º C.) to 140º F. (60º C.) -4º F. (-20º C.) to 140º F. (60º C.) -4º F. (-20º C.) to 140º F. (60º C.)
Max. pressure 30 PSI (2 bar) 30 PSI (2 bar) 30 PSI (2 bar) 30 PSI (2 bar) 30 PSI (2 bar) 30 PSI (2 bar)
Trans. material PVDF PVDF PVDF PVDF PVDF PVDF

Pulse Radar Sensors | Liquids | Intrinsically Safe

EchoPulse LR11 Pulse Radar Liquid Level Sensor EchoPulse LR16 Pulse Radar Liquid Level Sensor EchoPulse LR21 Pulse Radar Liquid Level Sensor EchoPulse LR26 Pulse Radar Liquid Level Sensor EchoPulse LR31 Pulse Radar Liquid Level Sensor
Series LR11 LR16 LR21 LR26 LR31
Classification Intrinsically safe Intrinsically safe Intrinsically safe Intrinsically safe Intrinsically safe
Media Liquids Liquids Liquids Liquids Liquids
Application Storage Storage Storage Process Lift station
Process condition Easy Difficult Difficult Extreme Difficult
Tank location and material Above grade metal or below grade in any tank material Above or below grade in any tank material Above or below grade in any tank material Above grade metal or below grade in any tank material Below grade in any tank material
Corrosive Yes Diluted Yes Yes Diluted
Range 32.8′ (10m) 98.4′ (30m) 65.6′ (20m) 114.8′ (35m) 98.4′ (30m)
Output 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA
Installation Tank adapter or flange Tank adapter or flange Flange Flange Bracket
Mount 1 1/2″ NPT 1 1/2″ NPT 3″, 4″ ANSI 4″, 6″ ANSI Bolt
Max. temperature 266° F. (130°C.) 302º F. (150º C.) 302º F. (150º C.) 266º F. (130º C.) 212º F. (100º C.)
Max. pressure 43.5 PSI (3 bar) 150 PSI (10 bar) 72 PSI (5 bar) 580 PSI (40 bar) Atmospheric
Ant. material PTFE 316L 316L & PTFE 316L & PTFE Nylon

Pulse Radar Sensors | Liquids | General Purpose

Series LR10 LR15 LR20 LR25 LR30
Classification General purpose General purpose General purpose General purpose General purpose
Media Liquids Liquids Liquids Liquids Liquids
Application Storage Storage Storage Process Lift station
Process condition Easy Difficult Difficult Extreme Difficult
Tank location and material Above grade metal or below grade in any tank material Above or below grade in any tank material Above or below grade in any tank material Above grade metal or below grade in any tank material Below grade in any tank material
Corrosive Yes Diluted Yes Yes Diluted
Range 32.8′ (10m) 98.4′ (30m) 65.6′ (20m) 114.8′ (35m) 98.4′ (30m)
Output 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA
Installation Tank adapter or flange Tank adapter or flange Flange Flange Bracket
Mount 1 1/2″ NPT 1 1/2″ NPT 3″, 4″ ANSI 4″, 6″ ANSI Bolt
Max. temperature 266° F. (130°C.) 302º F. (150º C.) 302º F. (150º C.) 266º F. (130º C.) 212º F. (100º C.)
Max. pressure 43.5 PSI (3 bar) 150 PSI (10 bar) 72 PSI (5 bar) 580 PSI (40 bar) Atmospheric
Ant. material PTFE 316L 316L & PTFE 316L & PTFE Nylon

Pulse Radar Sensors | Dry Bulk Solids | Intrinsically Safe

EchoPulse LR36 Pulse Radar Solids Level Sensor EchoPulse LR36 LR41 Pulse Radar Solids Level Sensor EchoPulse LR46 Pulse Radar Solids Level Sensor
Series LR36 LR41 LR46
Classification Intrinsically safe Intrinsically safe Intrinsically safe
Media Solids Solids Solids
Application Crusher, transfer station, bin Crusher, transfer station, stockpile, silo, bin Silo
Process dust Minimal Moderate Significant
Range 49.2′ (15m) 229.7′ (70m) 229.7′ (70m)
Output 4-20 mA, HART 4-20 mA, HART 4-20 mA, HART
Installation Bracket or gimbal flange Bracket or gimbal flange Gimbal flange
Mount 1 1/2″ NPT, 4″ or 5″ ANSI 1 1/2″ NPT, 4″ or 5″ ANSI 4″ or 5″ ANSI
Max. temperature 392º F. (200º C.) 752º F. (400º C.) 752º F. (400º C.)
Antenna type 4″ horn 4″ or 5″ horn 8″ or 10″ parabola
Ant. air purge No Yes No
Ant. dust shield No Option No
Ant. material 316L 316L with optional PTFE dust shield 316L

Guided Wave Sensors | Liquids | General Purpose

Series LG10-0 LG10-1 LG11-2
Classification General purpose General purpose General purpose
Media Liquids Liquids Liquids
Application Day tank, skid or machine, IBC or drum, process tank, waste sump Day tank, skid or machine, IBC or drum, process tank, waste sump Bulk storage
Probe type Rod Coaxial Cable
Probe material 316L 316L 316
Tank location and material Above grade metal or below grade in any tank material Above or below grade in any tank material Above grade metal or below grade in any tank material
Dirty, coating or crystallizing liquid Yes No Yes
Range 9.8′ (3m) 9.8′ (3m) 18′ (5.5m)
Output 4-20 mA 4-20 mA 4-20 mA
Mount 3/4″ NPT 3/4″ NPT 3/4″ NPT
Max. temperature 302° F. (150° C.) 302° F. (150° C.) 302° F. (150° C.)
Max. pressure 250 PSI (17 bar) 250 PSI (17 bar) 250 PSI (17 bar)

Liquid Level Switches

Series AXXX AX23 AX1X AX13 LU10 LZ12 LV10 LO10
Classification Intrinsically safe or general purpose General purpose Intrinsically safe or general purpose General purpose Intrinsically safe General purpose General purpose General purpose
Media Liquids Liquids Liquids Liquids Liquids Liquids Liquids Liquids
Type Multi-point package Multi-point package Single-point package Single-point package Ultrasonic sensor Vibration sensor Buoyancy sensor Optic sensor
Application Day tank, skid or machine, cooling tower, waste sump, process tank Day tank, skid or machine, cooling tower, waste sump, process tank Bulk storage, IBC or drum, neutralization tank Bulk storage, IBC or drum, neutralization tank Chemical Wastewater Water Secondary containment
Function Level switches Automatic fill or empty Level switch Level shut off Level switch Level switch Level switch Leak detection
Max. length 10′ (3m) 10′ (3m) 10′ (3m) 10′ (3m)
Supply 12-36 VDC 120/240 VAC 12-36 VDC 120/240 VAC 12-36 VDC 12-36 VDC 12-36 VDC
Contact (1-4) SPST relay or SPDT reed (1) SPDT latching relay (1-4) SPST relay or SPDT reed (1-4) SPST relay or SPDT reed (1) SPST relay (1) SPST relay (1) SPST reed (1) SPST relay
Rating 60 VA or 15 VA 250 VAC @ 10A 60 VA or 15 VA 250 VAC @ 10A 32 VDC (0.5A max) 60 VA (1A max) 15 VA (0.25A max) 60 VA (1A max)
Enclosure NEMA 4X (IP65) NEMA 4X (IP65) NEMA 4X (IP65) NEMA 4X (IP65) NEMA 6 (IP68) NEMA 6 (IP68) NEMA 6 (IP68) NEMA 6 (IP68)
Termination Conduit Conduit Conduit Conduit Cable Cable Cable Cable
Mount 2″ NPT (G) 2″ NPT (G) 2″ NPT (1 1/2″ G) 2″ NPT (1 1/2″ G) 3/4″ NPT (G) 3/4″ NPT (G) 3/4″ NPT (Rp) 3/4″ NPT (G)
Temperature -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.)
Max. pressure Atmospheric Atmospheric 150 PSI (10 bar) 150 PSI (10 bar) 150 PSI (10 bar) 150 PSI (10 bar) 25 PSI (10 bar) 150 PSI (10 bar)
Material PP PP PP / PVDF PP / PVDF PP / PFA PP-Ryton PP / PVDF PP / PFA

Level Controllers & Indicators

For Level Transmitters

Series LI55 LC52 LI25-2 LI23 LI40
Classification General purpose General purpose Intrinsically safe General purpose General purpose
Type Controller Controller Indicator Indicator Indicator
Application Display + control Display + control Display only Display + control Display only
Mount Panel mount Rail mount Panel mount Panel mount Panel mount
Display 6-digit LED 3.5-digit LED + bar graph 5-digit LCD 5-digit LCD 6-digit LCD
Supply 85-265 VAC, 12-24 VDC 120 / 240 VAC 12-30 VDC loop 12-30 VDC loop EchoPod sensor
Contact (0, 2, 4) SPDT relay (2) SPDT relays (2) SPST relays (optional)
Enclosure NEMA 4X faceplate NEMA 1 NEMA 4X faceplate NEMA 4X faceplate NEMA 4X faceplate

For Level Switches

Series LC40-42 LC90-92 LC10 LC11 LC05-06
Classification General purpose Isolation General purpose General purpose General purpose
Type Controller Controller Controller Controller Junction box
Application Pump, valve or alarm actuation; auto fill or empty with alarms Pump, valve or alarm actuation; auto fill or empty with alarms Pump, valve or alarm actuation Auto fill or empty Wiring termination
Mount Rail mount Rail mount Switch-Pak or sensor mount Smart Trak mount Switch-Pak, Smart Trak or sensor mount
Strobe Alert Option Option Option
Indication LED LED LED LED
Supply 120 / 240 VAC 120 / 240 VAC 120 / 240 VAC 120 / 240 VAC
Input (1-3) switches (1-2) switches (1) switch (2) switches (1-4) switches
Contact (1-3) SPDT relays (1 or 2) SPDT relays (1) SPDT relay (1) SPDT latching relay
Enclosure NEMA 1 NEMA 1 NEMA 4X NEMA 4X NEMA 4X